Skip to Main content Skip to Navigation
Conference papers

Methods applied to investigage the major UVCE that occured in the TOTAL refiner's Fluid Catalytic Cracking Unit at La Mède, France

Abstract : On monday November 9, 1992 at 5:20 a.m. a major U. V.C.E, occured in the Gas Plant of the TOTAL refinery's Fluid Catalytic Cracking unit at La Mede, France. The origin was a 25 cm2 break in the 8" by-pass of the absorber stripper column cooler; an amount of about 15 tons of LPG and light naphtha was released within 10 minutes, covering an area of 14000m2 including Gas Plant, cryogenic, propene and Merox units before being ignited on the FCC main furnace.
Document type :
Conference papers
Complete list of metadatas

https://hal-ineris.archives-ouvertes.fr/ineris-00971929
Contributor : Gestionnaire Civs <>
Submitted on : Thursday, April 3, 2014 - 1:32:32 PM
Last modification on : Thursday, April 3, 2014 - 1:32:32 PM
Long-term archiving on: : Thursday, July 3, 2014 - 1:45:52 PM

File

1995-035_hal.pdf
Files produced by the author(s)

Identifiers

  • HAL Id : ineris-00971929, version 1
  • INERIS : PU-1995-035

Collections

Citation

P. Michaelis, A. Hodin, Jean-François Lechaudel, P. Mejean. Methods applied to investigage the major UVCE that occured in the TOTAL refiner's Fluid Catalytic Cracking Unit at La Mède, France. 8. International Symposium Loss Prevention and Safety Promotion in the Process Industry, Jun 1995, Anvers, France. pp.365-376. ⟨ineris-00971929⟩