Interpretation of the loading effect in absorption filter photometers - dual spot aethalometer measurements - Ineris - Institut national de l'environnement industriel et des risques Accéder directement au contenu
Communication Dans Un Congrès Année : 2015

Interpretation of the loading effect in absorption filter photometers - dual spot aethalometer measurements

Grisa Mocnik
  • Fonction : Auteur
Luka Drinovec
  • Fonction : Auteur
Jean Sciare
Peter Zotter
  • Fonction : Auteur
Robert Wolf
  • Fonction : Auteur
André S.H. Prevot
  • Fonction : Auteur
I.J. Arnold
  • Fonction : Auteur
R.K. Chakrabarty
  • Fonction : Auteur
H. Moosmuller
  • Fonction : Auteur
A. Gregoric
  • Fonction : Auteur
M. Remskar
  • Fonction : Auteur
J. Vaupotic
  • Fonction : Auteur
Anthony D.A. Hansen
  • Fonction : Auteur

Résumé

Filter-based measurements of aerosol optical absorption are widely used to determine Black Carbon (BC) concentrations in real time. Measurements at multiple wavelengths permit the separation of contributions of BC from different combustion sources. Filterbased methods can suffer from non-linearity due increasing sample deposit on the filter. The dual-spot Aethalometer model AE33 provides a real-time determination of this loading effect, by determining the compensation parameter k in real time for each of the wavelengths. We present an interpretation of k in terms of aerosol composition. Optical properties of combustion aerosols were investigated under laboratory conditions. Optical properties of emitted aerosols varied greatly with the combustion regime. The type of combustion also influenced the parameter k, which is attributed to different particle coating thickness. Optical and chemical properties of aerosols were measured with high time resolution during summer and winter at different sites. The ratio of the sum of inorganic secondary and organic aerosol mass to BC (expected to be high for air parcels containing aged aerosols) correlates well with the parameter k measured by the AE33 at 880 nm. To investigate the influence of coating on parameter k, a drier and a thermodenuder were used to remove the coating. These results indicate that the compensation parameter k can be used for discrimination between fresh and aged aerosols.
Fichier non déposé

Dates et versions

ineris-01855096 , version 1 (07-08-2018)

Identifiants

  • HAL Id : ineris-01855096 , version 1

Citer

Grisa Mocnik, Luka Drinovec, Jean-Eudes Petit, Olivier Favez, Jean Sciare, et al.. Interpretation of the loading effect in absorption filter photometers - dual spot aethalometer measurements. 11. International Conference on Carbonaceous Particles in the Atmosphere (ICCPA), Aug 2015, Berkeley, United States. ⟨ineris-01855096⟩
110 Consultations
0 Téléchargements

Partager