A multi-band body-worn distributed radio-frequency exposure meter : design, on-body calibration and study of body morphology - Ineris - Institut national de l'environnement industriel et des risques Access content directly
Journal Articles Sensors Year : 2018

A multi-band body-worn distributed radio-frequency exposure meter : design, on-body calibration and study of body morphology

Reza Aminzadeh
  • Function : Author
Arno Thielens
  • Function : Author
Sam Agneessens
  • Function : Author
Patrick van Torre
  • Function : Author
Matthias van den Bossche
  • Function : Author
Stefan Dongus
  • Function : Author
Marloes Eeftens
  • Function : Author
Anke Huss
  • Function : Author
Roel Vermeulen
  • Function : Author
Paul Mazet
  • Function : Author
Elisabeth Cardis
  • Function : Author
Hendrik Rogier
  • Function : Author
Martin Roosli
  • Function : Author
Luc Martens
  • Function : Author
Wout Joseph

Abstract

A multi-band Body-Worn Distributed exposure Meter (BWDM) calibrated for simultaneous measurement of the incident power density in 11 telecommunication frequency bands, is proposed. The BDWM consists of 22 textile antennas integrated in a garment and is calibrated on six human subjects in an anechoic chamber to assess its measurement uncertainty in terms of 68% confidence interval of the on-body antenna aperture. It is shown that by using multiple antennas in each frequency band, the uncertainty of the BWDM is 22 dB improved with respect to single nodes on the front and back of the torso and variations are decreased to maximum 8.8 dB. Moreover, deploying single antennas for different body morphologies results in a variation up to 9.3 dB, which is reduced to 3.6 dB using multiple antennas for six subjects with various body mass index values. The designed BWDM, has an improved uncertainty of up to 9.6 dB in comparison to commercially available personal exposure meters calibrated on body. As an application, an average incident power density in the range of 26.7–90.8 μW·m −2 is measured in Ghent, Belgium. The measurements show that commercial personal exposure meters underestimate the actual exposure by a factor of up to 20.6.
Fichier principal
Vignette du fichier
2018-015.pdf (2.73 Mo) Télécharger le fichier
Origin : Publication funded by an institution
Loading...

Dates and versions

ineris-01863331 , version 1 (28-08-2018)

Identifiers

Cite

Reza Aminzadeh, Arno Thielens, Sam Agneessens, Patrick van Torre, Matthias van den Bossche, et al.. A multi-band body-worn distributed radio-frequency exposure meter : design, on-body calibration and study of body morphology. Sensors, 2018, 18 (1), pp.art. 272. ⟨10.3390/s18010272⟩. ⟨ineris-01863331⟩
32 View
88 Download

Altmetric

Share

Gmail Facebook Twitter LinkedIn More