Preliminary Risk Assessment of Hydrogen Refuelling Stations in a Multifuel Context
Abstract
The MultHyFuel Project [1], funded by the Fuel Cells and Hydrogen Joint Undertaking (FCH JU), aims to achieve
the effective and safe deployment of hydrogen as a net-zero alternative fuel, by developing a common strategy
for implementing Hydrogen Refuelling Stations (HRS) in multifuel context. The project contributes to the
harmonization of existing regulations code and standards (RCS) for industrial applications by generating
practical, theoretical and experimental data related to HRS, embedding regulatory and industrial stakeholders
to the project progress.
This paper presents a preliminary risk assessment performed for three different hydrogen refuelling
configurations, presented in project Deliverable 3.1 [2], each intended to be integrated into a multifuel station.
In terms of the hydrogen refuelling configurations, we discuss the following points:
• detail on typical components of hydrogen refuelling stations, such as compressor, high pressure buffer
storage, cooling system and dispenser,
• different modes of supply of hydrogen (high-pressure storage (trailers or bundles), hydrogen production by
electrolysis, and stationary liquid hydrogen storage),
• different operating conditions of the dispenser - i.e. flow and pressure - but only delivering compressed
gaseous hydrogen.
The objective of this preliminary risk assessment is not limited only to the identification of the major hazards -
and the consideration of various prevention and protection measures specific to the hydrogen installation - but
also, the mitigation measures to limit the potential of domino effects due to the potential hazards from other fuels
within the multifuel refuelling station. In this preliminary risk assessment, Hazards Identification (HAZID) for
hydrogen was implemented following the three steps below:
• the description of typical HRSs,
• the characterization of the potential hazards (substance, process...),
• and a previous H2 facility incident review to formulate lessons learned.
This example preliminary risk assessment illustrates how potential major accident scenarios were identified,
and presents proposed prevention or protection measures in order to reduce the occurrence of these scenarios
and mitigate the escalation of hazardous events”. In addition, some prevention and protection measures were
recommended when it was not possible to determine if they were universally implemented in Hydrogen
Refuelling Stations. Finally, knowledge gaps for the determination of Hazardous Area Classifications, likelihood
of hydrogen leaks and extent of consequences were highlighted, in order to be analysed and investigated
experimentally within future steps of the MultHyFuel Project [1].
Domains
Environmental Engineering
Origin : Files produced by the author(s)